Filter Portfolio
All Assets
Solar
Wind
Hybrid
Battery
Audit window: Jan 27 – Feb 9, 2026 · 15 observations
Total Revenue Loss
₹1,98,914
Capital leakage this period
Energy Variance
37,888 kWh
Actual vs expected generation gap
Portfolio Efficiency
38 %
Overall performance index
Operational Log
Record a plant observation below
Analyst Portfolio Review
Analyses your operational log for financial leakage and generates a formal 8-point executive report.
Portfolio Performance
Actual Generation vs Expected — Daily kWh
Actual
Expected
Financial Leakage Map
Daily revenue loss (₹)
Operational Efficiency Loss
Performance deviation trend
Operational Audit Report
Report Verified
1
Executive Performance Summary
Return to the Dashboard and click "Generate Enterprise Report" to run AI analysis and populate this section.
Total Capital Loss
₹1,98,914
Revenue leakage
Energy Variance
37,888
kWh generation gap
Incident Count
15
Logged events
Variance Rate
47%
Avg daily deviation
2
Operational Variance Log
| Date | Target (kWh) | Actual (kWh) | Loss (kWh) | Impact (₹) |
|---|
3
Strategic Insights & Root CausesAcute Revenue Leakage Events
High
Two critical events: 4,212 kWh variance on Feb 2 (₹22,113 loss) and 2,458 kWh on Feb 9 (₹12,892 loss). These two events represent 18% of total portfolio losses for the period.
Solar Asset Degradation Trend
High
Solar PV is progressively underperforming from late January. Daily harvest declining to 11–15% below target before the critical dip on Feb 9, indicating worsening efficiency loss.
Hybrid Systematic Underperformance
Medium
Hybrid assets show a consistent flat underperformance of ~10% daily. This consistency points to a configuration or capacity limitation rather than intermittent hardware faults.
Probable Causes
Inverter string failure or blown fuses may explain the Feb 8 Solar incident — thermal imaging recommended.
Grid curtailment or unscheduled turbine maintenance likely caused the Feb 2 Wind variance drop.
Progressive soiling or tracker misalignment explains the widening baseline Solar variance over 2 weeks.
Possible EMS control latency or dispatch logic anomalies causing consistent Hybrid underperformance.
4
Actionable Recommendations1
Solar Inverter String Diagnostic
Primary Concern
Action
Dispatch field technician for thermal imaging and IV curve tracing. Review MPPT logs for clipping events between Jan 28–Feb 9.
Action Impact
Restores an estimated ₹45,000–₹70,000/month in lost generation revenue if inverter fault confirmed and replaced.
2
Wind Variance Event (Feb 2) — RCA
Primary Concern
Action
Request immediate Root Cause Analysis from the O&M provider to confirm if the 42% drop was due to grid curtailment or machine fault.
Action Impact
Determines if the loss is recoverable via downtime claims or requires physical repair and part replacement.
3
Hybrid Efficiency Gap — EMS Audit
Primary Concern
Action
Audit the Energy Management System setpoints for the Hybrid plant and verify optimal dispatch logic configuration.
Action Impact
Recovers the consistent ~10% daily energy loss, worth approximately ₹18,000–₹22,000 per month at current tariff.
A · RENEWAI AUDIT SYSTEM V2.5
© 2026 RenewAI Enterprise Solutions
Live Alerts
AI-detected anomalies and operational warnings
HVAC / Inverter Unit 3 drawing 340% above baseline power. Possible fault or refrigerant leak. Estimated excess cost: ₹3,200/day.
● 2 minutes ago · HIGH PRIORITY
Solar array (Sector B) underperforming by 18% vs irradiance forecast. Possible soiling or partial shading event. Check tracker alignment.
1 hour ago · MEDIUM
Wind turbine T-04 reporting SCADA communication timeout. Last telemetry received 47 minutes ago. Verify connectivity and site access.
47 minutes ago · MEDIUM
Quarterly audit report due in 8 days. All operational log data is complete and verified. Proceed to Analyst Report to generate.
1 day ago · LOW
Portfolio Overview
All active assets across solar, wind and hybrid categories
☀️ Solar Portfolio
Installed Capacity2.4 MWp
Feb Generation48,320 kWh
CUF22.4%
Revenue Loss₹82,400
💨 Wind Portfolio
Installed Capacity3.6 MW
Feb Generation112,800 kWh
CUF34.7%
Revenue Loss₹72,100
⚡ Hybrid Portfolio
Installed Capacity1.8 MWp
Feb Generation31,440 kWh
CUF19.1%
Revenue Loss₹44,414